QQ: 2668349228
Wechat: SUBS0759
Email: Sales@dgsubs.com
Numerical control tenon machine, chair tenon machine and processing method of all kinds of abnormal alarm
Using numerical control tenon machine, we must know 6 ways of alarm abnormal.
If the system can detect the malfunction in the operation of the tenon and tenon machine, the equipment will stop automatically and be used as the manufacturer. Of course, the quality of the machine is of no loss. For example, CPU damage and so on, the machine will not be able to detect the fault, also can not output alarm information, when the above phenomenon, please contact the manufacturer Service Hotline: 0769-85630696, we will do our best to solve you.
When the CNC tenon and tenon machine, the equipment will automatically enter the above fault page when the equipment has the above fault, you can use the following methods according to the specific alarm information.
1: "emergency stop switch is depressed" -- alarm, check whether the emergency switch is pressed, if clockwise rotation stops, the switch will automatically pop up.
2: "air pressure is too low", check whether the air intake pipe is connected, and leak gas. After troubleshooting, press "reset fault".
3: "X axis servo alarm" "Z axis servo alarm", press "fault reset" button generally can clear the fault, such as can not reset, please close the power supply more than 5 seconds, then open the power, use servo reset, servo alarm general situation is more complex, this time can contact the manufacturer.
4: "all the limits alarm", the above alarm, return to the control page, manually move the alarm shaft out of the limit, and then press "reset fault".
5: "oil injector without oil" -- alarm, for example, please add guideway oil to the lubricator.
6: "overload of spindle motor" - alarm. The main shaft thermal relay protection action is caused by spindle motor. The main reasons are: the machining speed is too high, the cutting amount is too large, and the motor is burnt out.